Telecordia GR-326-CORE for fiber optic connectors

Telecordia GR-326-CORE for fiber optic connectors

You will need an insertion / return loss test system to go along with our chamber to do these tests.? We recommend the Optical Component Environmental Test System from JDS Uniphase. It is ready to work with an LAB COMPANION environmental chamber, making the perfect optical components environmental test system for long term testing to Telcordia (Bellcore) standards GR-326, 1209, 1221.?

All the required tests can be done by our?quality temperature/humidity chambers?model

Paragraph Title Description Benchtop Models Reach-in Models
4.4.2.1 Thermal Age Test 85°C Any?benchtop?or?ovens Any?quality temperature/humidity chambers?or?Faster Temperature Cycling Chambers
4.4.2.2 Thermal Cycle Test ?-40 to 75°C ? Any?quality temperature/humidity chambers?or?Faster Temperature Cycling Chambers
4.4.2.3 Humidity Aging Test 75°C/95% Any?benchtop?or?ovens Any?quality temperature/humidity chambers?or?Faster Temperature Cycling Chambers
4.4.2.4 Humidity/Condensation Cycling Test ?-10 to 65°C w/ condensation ?see note below Any?quality temperature/humidity chambers?or?Faster Temperature Cycling Chambers
4.4.2.5 Dry-out Step 75°C Any?benchtop?or?ovens Any?quality temperature/humidity chambers?or?Faster Temperature Cycling Chambers
4.4.4.1 Dust Test Arizona fine dust ? ?
4.4.4.2 Adhesive Test 65°C Any?benchtop?or?ovens Any?quality temperature/humidity chambers?or?Faster Temperature Cycling Chambers

For test 4.4.2.4, we don't recommend our benchtop series due to the requirement for heat-up as fast as possible (3.75°C/min. minimum) in order to create condensation.? For Platinous models, a special, but inexpensive modification is required.