Telecordia GR-63-CORE for network switching systems (NEBS)

Telecordia GR-63-CORE for network switching systems (NEBS)

For rack-component-level testing, your best bet is our?quality temperature/humidity chambers?;Faster Temperature Cycling Chambersmodels. For fully loaded racks, a?walk-in chamber?is needed.

?

Paragraph Title Description Benchtop Models Reach-in Models Other Models
5.1.1.1 Low-Temperature Exposure and Thermal Shock Hold the equipment at -40°C for 72 hours, then remove to ambient room temperature Almost every benchtop Any?quality temperature/humidity chambers Walk-in
5.1.1.2 High-Temperature Exposure and Thermal Shock Hold the equipment at 70°C for 72 hours, then remove to ambient room temperature Any?benchtop?or?ovens Any?quality temperature/humidity chambers?or?Faster Temperature Cycling Chambers Walk-in
5.1.1.3 High Relative Humidity Exposure Maintain 40°C and 90-95% RH for 96 hours, with controlled heat-up and cool-down Any humidity model Any?quality temperature/humidity chambers Walk-in
5.1.2 Operating Temperature and Relative Humidity There are 14 steps to the test sequence, cycling from -5 to 50°C, as well as humidity.? One step requires holding 5°C/<15%RH. ? Any?quality temperature/humidity chambers Walk-in
5.1.3 Operating Altitude Twelve step cycling test of temperature and humidity. 25°C to 50°C and up to 4,000 meters above sea level. ? Altitude?or?Walk-in Walk-in

Because 5.1.2 and 5.1.3 require your equipment to be operating, these become a challenging application for a test chamber due to the heat generated.

The altitude test is new for Issue 2 of this specification.