Telecordia GR-1209-CORE for passive fiber optic components

Telecordia GR-1209-CORE for passive fiber optic components

You will need an insertion / return loss test system to go along with our chamber to do these tests. We recommend the Optical Component Environmental Test System from JDS Uniphase. It is ready to work with an LAB COMPANION environmental chamber, making the perfect optical components environmental test system for long term testing to Telcordia (Bellcore) standards GR-326, 1209, 1221. All the required tests can be done by our?quality temperature/humidity chambers?model

Paragraph Title Description Benchtop Models Reach-in Models
5.4.1.1 Temperature-Humidity Aging 75°C/90% for 168 hours
(or 85°C/85%)
Any humidity model Any?quality temperature/humidity chambers?or?Faster Temperature Cycling Chambers models
5.4.1.5 Temperature Cycling -40 to 70°C at ~1°C per minute, 10 cycles Almost every benchtop Any?quality temperature/humidity chambers?or?Faster Temperature Cycling Chambers models
5.4.2.1 Temperature-Humidity Cycle
(for controlled environments)
-10 to 60°C and 20 to 85%RH, 42 cycles Any?quality temperature/humidity chambers?or?Faster Temperature Cycling Chambers models
5.4.2.2 Temperature-Humidity Cycle
(for uncontrolled environments)
-40 to 85°C and 20 to 85%RH, 42 cycles Any?quality temperature/humidity chambers?or?Faster Temperature Cycling Chambers models
5.4.2.4 Temperature Effects on DWDM Components
(for controlled environments)
?-10 to 60°C
1-2°C per minute, one cycle
Almost every benchtop Any?quality temperature/humidity chambers?or?Faster Temperature Cycling Chambers models
5.4.2.5 Temperature Effects on DWDM Components
(for uncontrolled environments)
?-40 to 85°C
1-2°C per minute, one cycle
Almost every benchtop Any?quality temperature/humidity chambers?or?Faster Temperature Cycling Chambers models